The rule: power and duty
Two questions decide whether an appliance deserves its own circuit: how much power it draws, and how it works over time. Heating elements, motors and compressors draw high steady current, start with inrush peaks and run for hours — they are bad neighbours for a shared group.
Short, light loads behave the opposite way: phone chargers, lamps, a TV or a laptop never coincide at full power, so room sockets share one group calmly. The design task is to separate the first category from the second before a single cable is drawn.
The third question is coincidence: cooker and oven run together for hours on holidays, while a vacuum cleaner and an iron work in turns and briefly. Split appliances with matching peaks across groups even at modest power each — it is the sum of peaks that trips the breaker.
Write down every heavy appliance first — name, rough power, operating mode — and only then group the leftovers by room. This order prevents the classic mistake: a “general sockets” group that secretly feeds a washer.
Kitchen: cooker, oven, dishwasher
The kitchen concentrates the heaviest loads in the home. The electric cooker and the oven each get their own group — they heat for a long time at high power, and sharing a line with anything else guarantees overload during holiday cooking.
The dishwasher deserves its own circuit too: heating plus pump next to water. Add the microwave and the kettle zone thoughtfully — they are short-duty but powerful, so they sit on the general kitchen sockets group with a honest load count, never together with the cooker.
Small built-in appliances — hood, fridge electronics, ignition — can share a lightly loaded group. The rule of thumb: anything that heats water or food at kilowatts gets a dedicated line; everything else shares by calculation.
Wet and heavy: washer, dryer, boiler
The washing machine combines a motor, a heater and water: its own group is the default, and sharing it with a dryer on one line is asking for tripping. Two heating appliances must live on separate breakers.
The storage water heater (boiler) runs for hours at steady high power — a dedicated line with no neighbours. Instantaneous heaters are stricter still: their short bursts are so powerful that the group, the cable and the breaker are sized for them alone.
Bathroom sockets — hair dryer, shaver — stay on a separate small group with residual-current protection rather than hanging off the washer line. Wet rooms forgive no shortcuts: one fault must not take down the whole bathroom.
Climate: air conditioning, floor heating
An air conditioner runs for hours in summer heat — exactly when the grid is stressed. Its own circuit isolates the steady compressor load and lets you switch climate equipment without touching lighting and sockets.
Electric floor heating is a long, distributed, high-power load: each zone or room gets its own group through its thermostat. Mixing floor heating into general sockets hides kilowatts inside an “ordinary” group and overheats the first cable segment.
Ventilation units and heated towel rails are lighter but continuous — put them on the climate or utility group deliberately, not “wherever there is a free socket”. Document the choice so the next electrician understands the logic.
Light loads that share calmly
After the heavyweights are separated, the rest groups easily. Room lighting splits into one or two groups by zone; general sockets group by room — living room, bedroom, study. These loads are small and never peak together.
Electronics corners — TV zone, desk with computer, chargers — share the room group without drama. The same goes for the hallway, balcony and utility sockets: low power, short duty, no heating.
Keep one principle: a shared group must stay boring. If any device on it starts heating water or air for hours, it graduates to its own line. Review the groups whenever a new appliance arrives — the checklist is a living document, not a one-time ritual.
Building the final group list
| Group | Typical members | Note |
|---|---|---|
| Lighting 1–2 | Rooms by zone | Split so one fault never darkens the flat |
| Sockets by room | Living, bedroom, study | Light loads only |
| Kitchen power | Cooker, oven, dishwasher | Each heavyweight separate |
| Wet and heavy | Washer, boiler | Never washer + dryer together |
| Climate | AC, floor heating | By zone, via thermostats |
Walk the flat room by room with this table and cross off every appliance — nothing should remain “connected somewhere”. Count the groups, check the panel has spare ways for the future, and only then draw routes.
GorkyCAD keeps the list honest: group loads feed the deterministic calculation engine — currents, short-circuit, voltage drop within 5%, heating — and the auto-panel selects devices and balances phases from the same model. The single-line diagram, cable schedule and estimate follow automatically.
From checklist to documents
A group list becomes a project when it is drawn: sockets and luminaires on the plan, routes to the panel, breakers in the panel scheme. Each group label must match across plan, single-line diagram, cable schedule and estimate — mismatches are the classic handover failure.
Before printing, run the automatic checks — 25 checks against IEC 60364 in the English base — and read every warning as a question, not as noise. Calculations are advisory: the engineer approves the final result.
Then export the handover set: open the editor, verify the groups and warnings, and download the PDF package — plan, single-line, panel scheme, specification, cable schedule and estimate. Tariffs are on the pricing page (Pro €40/mo, start free).
Keep the checklist with the project: when the client buys a dryer or a second air conditioner next year, you will see at once whether a free group exists or a visit is needed. A returning happy client is cheaper than any advertising.
FAQ
Does a dishwasher need its own circuit?
Usually yes: a dishwasher combines heating and a pump with a wet environment nearby. A separate group with residual-current protection makes the kitchen safer and keeps a fault from killing the neighbouring sockets.
Washer plus dryer on one group?
It is better to separate them: two heating appliances on one group invite overload and nuisance tripping. If the panel has no free ways, at least never run both machines at once — but plan a separate group at the next panel upgrade.
Does an air conditioner always get its own circuit?
As a rule, yes — a split-system draws a steady load for hours and is sensitive to disturbances. Its own breaker simplifies protection and lets you isolate the climate equipment without touching the rest of the flat.
How many circuits does a normal flat need?
A typical flat ends up with eight to twelve groups: lighting split by zones, general sockets by room, plus dedicated lines for the cooker, oven, washer, boiler and AC. The exact count follows the loads, not a norm — the checklist below shows how to build it.