What is checked
Panel: input protection, RCD, labeling, scheme. Sockets: grounding, polarity, RCD groups. Cable: cross-sections, installation method. Bathrooms: zones and IP.
Documents
Electrical project, test protocol (insulation resistance, RCD trip, grounding), equipment certificates, panel passport.
Typical violations
No RCD on socket circuits; PEN splitting without re-grounding; wrong cross-sections; no labels; no test protocol; violations of bathroom zones.
How to prepare
Pass the test protocol before the inspection; check the panel per the scheme; the inspector compares the installation with the project.
If violations found
The inspector issues a list of deficiencies with a deadline. After the fix — a re-inspection, usually free.