IP44, IP65, IP68. The numbers sit on every outdoor light, bathroom fan, and junction box, and most buyers read them as a single score where bigger is better. It is not. The two digits measure completely different threats, and chasing the highest number often buys the wrong protection at the wrong price.
This guide decodes both digits, shows where each common rating belongs around the house and on industrial sites, and explains the traps: why IP68 is worse than IP65 in some places, why bathroom zones matter more than the raw number, and which details like UV resistance and drainage decide real lifetime.
1. What the two digits actually measure
The code comes from IEC 60529. The first digit rates protection against solids and access to live parts, from 0 to 6. The second digit rates water, from 0 to 9. IP44 means solid objects over 1 mm cannot enter and splashing water from any direction is harmless. IP65 means dust tight and water jets are harmless. The digits are independent: a device can be excellent against dust and weak against immersion, or the reverse in theory.
Read them separately every time. IPX4 tells you nothing about dust. IP6X tells you nothing about water. Only the full pair describes the enclosure.
2. First digit: solids from 0 to 6
Zero means no protection. One blocks a hand, two a finger, three tools and wires over 2.5 mm, four wires and screws over 1 mm. Five is dust protected: some dust may enter but not enough to harm operation. Six is dust tight: no dust enters at all. For homes the practical jump is between 4, which stops insects and wire ends, and 5 or 6, which keeps out construction dust and keeps mechanisms working for years.
Access protection matters too: ratings 1 to 4 include probes shaped like fingers, tools, and wires. A curious child with a screwdriver is exactly what digit 4 is tested against.
3. Second digit: water from 0 to 9
One is dripping water, two is dripping tilted 15 degrees, three is spraying, four is splashing from any direction, five is water jets from a nozzle, six is powerful jets, seven is temporary immersion to 1 m for 30 minutes, eight is continuous immersion under manufacturer stated conditions, nine is high pressure hot jets. Most buildings live between 4 and 6. Ratings 7 and 8 need the depth and time from the datasheet, because IP68 without stated conditions is an incomplete claim.
| Rating | Solids | Water | Typical use |
|---|---|---|---|
| IP20 | Fingers | None | Indoor dry rooms, inside cabinets |
| IP44 | 1 mm objects | Splashing | Bathroom zone 2, eaves, porches |
| IP55 | Dust protected | Jets | Carports, workshops |
| IP65 | Dust tight | Jets | Outdoor walls, gardens, industry |
| IP66 | Dust tight | Powerful jets | Washdown areas, farms |
| IP68 | Dust tight | Immersion per datasheet | Ponds, pits, flood zones |
4. Worked example: picking three fittings
Porch wall light under a 600 mm overhang: rain arrives as splash and wind driven spray, dust is normal street dust. IP44 is the honest minimum, IP65 adds margin for pressure washing the wall. Bathroom mirror light 1.2 m from the shower head: splashing is certain, immersion is not, so IP44 suffices and IP65 gives reserve. Garden spike light in a lawn that floods to 100 mm after storms: splashing ratings fail because the fitting sits in standing water for hours, so IP67 with stated 1 m 30 min, or IP68 with explicit depth and time, is the correct call. Three locations, three different answers, none of them the maximum number.
5. Bathrooms: zones beat raw numbers
IEC 60364-7-701 divides bathrooms into zones. Zone 0 is inside the bath or shower tray and needs at least IPX7. Zone 1 above the bath to 2.25 m needs at least IPX4, or IPX5 where water jets are used for cleaning. Zone 2, the 600 mm band around zone 1, needs at least IPX4. Outside the zones, ordinary indoor rules apply but steam and condensation still favour IP44 for longevity.
The zone decides the minimum. Fitting an IP68 light inside zone 1 is allowed but pointless if its driver sits in a damp ceiling void at IP20. Protect the whole chain, not just the visible face.
| Location | Minimum rating | Sensible pick |
|---|---|---|
| Inside shower tray | IPX7 | IP67 low voltage |
| Above bath to 2.25 m | IPX4 | IP44 or IP65 |
| 600 mm around bath | IPX4 | IP44 |
| Outdoor wall, rain | IPX4 | IP65 |
| Garden in flood dip | IPX7 | IP67 or IP68 with depth stated |
| Dusty workshop | IP5X | IP65 |
6. Why IP68 is not always better
An IP68 seal that survives immersion can still fail under a jet, because the tests differ: immersion is static pressure, jets are dynamic impact on seals and cable glands. Manufacturers test the combinations they claim, so IP68 alone does not imply IP65. Devices rated IP68 and IP69K exist precisely because one test does not cover the other. For a wall washed with a hose, IP65 beats a bare IP68 claim.
Sealed boxes also trap condensation. A perfectly gasketed IP68 enclosure with daily temperature swings breathes through its cable glands and collects water inside unless it has a drain or breather valve. Outdoor IP65 boxes with the drain hole at the bottom opened last longer than sealed IP68 boxes installed without drainage.
7. Details that decide lifetime
Ultraviolet resistance of the plastic, stainless or coated screws, the cable gland rating matching the box rating, and the mounting orientation all matter as much as the headline number. A gland rated IP68 on a box rated IP65 gives a IP65 assembly at best, and often worse if the cable diameter does not match the gland seal range. Check the whole assembly rating on the datasheet, not the best component.
Temperature range and impact rating IK matter outdoors. A box rated IP65 down to minus 5 degrees turns brittle at minus 20, and the first frost cracks the seal. Cold climate sites need the low temperature figure in writing.
8. Assumptions and when this does not apply
This guide assumes ordinary buildings and light industry using IEC 60529 ratings, competent installation per manufacturer instructions, and intact seals maintained over time. It does not cover explosive atmospheres, where Ex ratings govern alongside IP; submersible pumps and divers equipment with their own standards; or high pressure steam cleaning in food plants, which needs IP69K procedures. Ratings apply to the product as tested; site modifications such as extra drilled holes void them.
9. Mini case: the drowned garden lights
A homeowner fitted eight IP65 spike lights along a path that dipped through a lawn hollow. After the first autumn storm the hollow held 80 mm of water for a day and four drivers failed. The fittings were genuine IP65, correctly installed. The failure was selection, not quality: jets protection does not cover standing water. The fix kept IP65 for the five heads on high ground and moved the three in the dip to IP67 bollards with the joint above flood level. Two years on, zero failures. The lesson: map water behaviour first, then pick the number.
10. Checklist before buying
Write down solids risk, water form, immersion depth and time, jet exposure, dust load, UV and frost, and the gland and mounting details. Match the pair of digits to that list, check the datasheet states depth and time for any 7 or 8 claim, and confirm the assembly rating including glands. Photograph the installed seal positions for the handover file. A five minute list prevents most wrong purchases.
11. Cost of getting it wrong
Price differences between ratings are smaller than the cost of one failure call. A decent IP44 bulkhead and its IP65 equivalent often differ by the price of a lunch, while a single return visit with a ladder, a replacement driver, and a dissatisfied customer costs ten times more. The expensive mistake is not over specifying by one step; it is fitting IP44 where standing water or jets are certain and replacing the fitting twice.
Work it for a garden run of six lights. Option A is six IP65 spikes at a modest unit price. Option B is three IP65 on high ground plus three IP67 bollards for the wet hollow at a higher unit price. Option B costs roughly one third more up front. After one storm season, option A has four failed drivers and one full day of rework, while option B has zero. Over three years option B is cheaper by a wide margin even before counting reputation. The same arithmetic applies indoors: one IP44 fan that survives steam beats two cheap unrated fans that seize.
Buy once by writing the water behaviour in one sentence per location, then matching the pair of digits to that sentence. Keep the datasheets with the handover so the next electrician knows why each rating was chosen and does not downgrade them during maintenance.
One last check costs nothing: after mounting, hose or splash the installed fitting the way weather will, watch the seals and drainage for ten minutes, and only then sign off. Field verification catches pinched gaskets and wrong gland sizes that datasheets can never show.
Try it on your own plan: open the free demo at https://gorkycad.com/cad/?demo=1&lang=en — draw rooms, place the board, run checks and export a PDF parts list.
Frequently asked questions
Is IP68 better than IP65 for outdoor walls?
Not necessarily. IP65 covers water jets, IP68 covers immersion under stated conditions. For rain and hose washing, IP65 is usually the right rating; IP68 alone does not prove jet resistance.
What IP do I need in a bathroom?
Follow zones: zone 0 needs IPX7, zones 1 and 2 need at least IPX4, or IPX5 with cleaning jets. Outside zones, IP44 gives good longevity against steam.
Does IP68 mean waterproof forever?
No. It means immersion passed under the depth and time the manufacturer states. Without those figures the claim is incomplete, and condensation still needs drainage.
Can I drill extra holes in an IP65 box?
Only with rated glands fitted per instructions and the assembly rechecked. Unsealed extra holes void the rating.
What matters more than the headline number?
Glands, orientation, UV and frost ratings, drainage, and maintenance of seals. The assembly rating is the lowest rated part of the chain.