China: electrical installation rules (GB 50054, GB 50303, JGJ 16)

Chinese electrical codes: GB 50054, GB 50303, JGJ 16, GB/T 16895 (IEC 60364). 220/380 V, GB 1002 sockets, TN-C-S/TT earthing, 30 mA RCDs.

🇷🇺 PUE — Rules for Electrical Installations (7th ed.)🕰️ PUE-6 — Rules for Electrical Installations (6th ed., 1985)🇺🇸 NEC — National Electrical Code (NFPA 70)🇪🇺 IEC 60364 / HD 60364 (EU national codes)🌎 NOM-001-SEDE, NBR 5410, AEA 90364, RETIE, NCh 4, CNE🇨🇳 GB 50054, GB 50303, JGJ 16, GB/T 16895 (IEC 60364)🇮🇳 IS 732

Key facts

DocumentGB 50054, GB 50303, JGJ 16, GB/T 16895 (IEC 60364)
Voltage220/380 V
Frequency50 Hz
SocketsGB 1002 (3 flat pins)
EarthingTN-C-S, TN-S, TT

Terminology in the native language

Native termTransliterationEnglish translation
电压diànyāvoltage
电流diànliúcurrent
接地jiēdìearthing / grounding
漏电保护器lòudiàn bǎohùqìresidual current device (RCD)
断路器duànlùqìcircuit breaker
配电箱pèidiànxiāngdistribution board
电线diànxiànwire
电缆diànlǎncable
插座chāzuòsocket outlet
开关kāiguānswitch
短路duǎnlùshort circuit
绝缘juéyuáninsulation
变压器biànyāqìtransformer
负荷fùhèload
防雷fángléilightning protection
低压dīyālow voltage (up to 1 kV)

Chinese standards system

China's electrical rules are national standards GB (Guóbiāo, 国家标准) and industry JG series:

Voltage and systems

The household network is 220/380 V, 50 Hz. Sockets follow GB 1002: three flat pins (two line + earth, 10 A and 16 A). Earthing: TN-C-S, TN-S, TT — TN-S/TN-C-S for new buildings, TT common in rural areas.

Protection and RCDs

RCDs (漏电保护器) are mandatory per GB 50096 (residential): 30 mA for socket circuits, 10 mA for bathrooms, 300 mA fire-protection RCD at the intake. Breakers follow GB 10963 (IEC 60898 equivalent).

Wiring and materials

Cables per GB/T 5023, GB/T 12706: copper preferred, aluminium limited (≥16 mm²). Concealed wiring in conduits (PVC/steel); phase colors historically yellow/green/red, new projects follow IEC; PE — green-yellow.

China vs PUE

ParameterChinaRussia (PUE)
Voltage220/380 V, 50 Hz230/400 V, 50 Hz
SocketsGB 1002 (3 flat pins)Type C/F
RCD in housing30 mA (10 mA bathrooms)30 mA (10 mA bathrooms)
BasisOwn GB + IEC 60364PUE-7 + GOST R 50571

Inspection and certification

Designs undergo review (施工图审查), installation is controlled by construction inspection; completed installations pass acceptance tests (GB 50303). Equipment requires CCC (China Compulsory Certification) certificates.

Related references

Clause-by-clause review

Translation of key sections and clauses with numbers:

Design with GorkyCAD Pro

Automatic single-line diagrams, PUE/GOST/IEC calculations, specification and PDF — from one model.

Start free

Data is for reference. Final design decisions must follow current regulations and a qualified engineer.
Reference · World electrical installation rules