US NEC (NFPA 70): National Electrical Code

US National Electrical Code (NEC, NFPA 70): 120/240 V 60 Hz, AWG wiring, GFCI and AFCI protection, ampacity tables, differences from PUE and IEC.

🇷🇺 PUE — Rules for Electrical Installations (7th ed.)🕰️ PUE-6 — Rules for Electrical Installations (6th ed., 1985)🇺🇸 NEC — National Electrical Code (NFPA 70)🇪🇺 IEC 60364 / HD 60364 (EU national codes)🌎 NOM-001-SEDE, NBR 5410, AEA 90364, RETIE, NCh 4, CNE🇨🇳 GB 50054, GB 50303, JGJ 16, GB/T 16895 (IEC 60364)🇮🇳 IS 732

Key facts

DocumentNEC — National Electrical Code (NFPA 70)
Voltage120/240 V
Frequency60 Hz
SocketsNEMA 5-15R etc.
EarthingTN-C-S (grounded neutral + equipment ground)

Terminology in the native language

Native termTransliterationEnglish translation
ampacityampacitymaximum current a conductor can carry
branch circuitbranch circuitfinal circuit from breaker to outlets
feederfeedersupply circuit between panel and distribution
service entranceservice entrancepoint where utility power enters
grounding electrodegrounding electrodeearth electrode (rod, plate)
bonding jumperbonding jumperequipotential bonding conductor
GFCIGFCIground-fault circuit interrupter (RCD)
AFCIAFCIarc-fault circuit interrupter
raceway / conduitraceway / conduitpiping or tray for wires
AWGAWGAmerican Wire Gauge (wire size)
disconnectdisconnectload-break switch at equipment

What is NEC

NEC (National Electrical Code), officially NFPA 70, is the US national electrical installation code developed by NFPA. It is updated every 3 years (current edition — 2023). NEC is mandatory in most states and is the basis for many Latin American and Asian codes. Canada has a close code: CE Code (CSA C22.1).

Voltage and systems

The US household network is 120/240 V, 60 Hz, single-phase three-wire (split-phase): two 120 V hot legs to neutral and 240 V between them. Sockets follow NEMA: 5-15R (15 A, 125 V, grounded), 5-20R (20 A), 14-50R (50 A, for stoves and EV chargers). Wires are sized by AWG (the smaller the number, the thicker the wire).

GFCI and AFCI — mandatory protection

A key NEC feature is the broad GFCI (Ground-Fault Circuit Interrupter, an RCD equivalent) requirement: bathrooms, kitchens, outdoors, garages, basements, near sinks (art. 210.8), tripping at 4–6 mA. The second unique device is AFCI (Arc-Fault Circuit Interrupter): arc-fault protection mandatory for bedrooms and most dwelling circuits (art. 210.12). Both are built into breakers or receptacles.

Wiring and ampacity

Ampacity follows NEC tables (Table 310.16 for copper/aluminium at 60/75/90 °C). Installation rules: NM cables (Romex®) in dry locations, metal conduit (EMT/RMC) and raceways elsewhere; grounding and bonding per art. 250 (grounding electrode, bonding jumper).

NEC vs PUE vs IEC

ParameterNEC (US)PUE (RF)
Household voltage120/240 V, 60 Hz230/400 V, 50 Hz
Conductor sizesAWG (12 AWG ≈ 3.31 mm²)mm² (1.5, 2.5, 4…)
Socket protectionGFCI + AFCIRCD 30 mA
ReceptaclesNEMA 5-15RType C/F
Update cycle3 yearsChapter by chapter

Countries using NEC

NEC-based rules apply in the USA (NFPA 70), many Latin American states (Mexico NOM-001-SEDE, Colombia NTC 2050, Peru CNE), the Philippines (PEC), several Caribbean and Middle East countries. Canada uses its own CE Code (CSA C22.1), structurally close to NEC.

Related references

Clause-by-clause review

Translation of key sections and clauses with numbers:

Design with GorkyCAD Pro

Automatic single-line diagrams, PUE/GOST/IEC calculations, specification and PDF — from one model.

Start free

Data is for reference. Final design decisions must follow current regulations and a qualified engineer.
Reference · World electrical installation rules