IEC 60364-7-702: zones 0–3, SELV 12 V in water, IPX8 luminaires, 30 mA RCDs.
| Document | IEC 60364-7-702 Pools and fountains |
| Edition | 2019 |
| Status | Current (IEC 60364-7-702) |
| Issued by | IEC |
| Applies to | Pools and fountains: zones 0–3, IPX8 luminaires, RCDs |
| № | Chapter / section |
|---|---|
| 702.30 | Pool zones |
| 702.41 | Shock protection |
| 702.512 | Equipment and luminaires |
Zone 0 — water volume; zone 1 — 2 m from pool walls; zone 2 — 1.5 m beyond.
SELV ≤ 12 V in zones 0–1; sockets in zone 2+ via 30 mA RCD; supplementary bonding of metal parts.
Luminaires: zone 0 — IPX8; zone 1 — IPX4; zone 2 — IPX2/4.
Automatic single-line diagrams, PUE/GOST/IEC calculations, specification and PDF — from one model.
Start freeData is for reference. Final design decisions must follow current regulations and a qualified engineer.
← Back to the country: Europe: IEC 60364 and national codes (BS 7671, DIN VDE 0100, NF C 15-100) · World electrical installation rules